High-Low Temperature Test Chambers
-
-
Electronics/ Electrician /Instrument
-
Material/ Semiconductor
-
School/ Hospital/ Chemical Industry
-
Environmental Protection
-
Livestock/ Aquatic Products
-
Temperature Deviation±2.0℃
(When no load and temperature is stable) -
Test Ambient Temperature+25℃
-
Temperature Range-20℃~150℃
-
Cooling Time≤45 min
(+20℃→-20℃) -
Heating Time≤60 min
(-20℃→+150℃) -
Temperature Fluctuation≤1℃
(When no load and temperature is stable)
Typical Model | ||||
MGDW-150-20H | MGDW-150-40H | MGDW-225-20H | MGDW-225-40H | MGDW-225-70H |
MGDW-408-20H | MGDW-408-40H | MGDW-408-70H | MGDW-800-20H | MGDW-800-40H |
MGDW-800-70H | MGDW-1000-20H | MGDW-1000-40H | MGDW-1000-70H |
Suitable is the best. High and Low Environmental Test Chambers .
WGDW SERIES High-Low Environmental Test Chambers (Coin cell All-in-one)
Volume: 150L/225L;
Material coding: WGDW-225L-40-mA160CH;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~85℃;
Temperature Fluctuation: ≤1℃ (no load and stable temperature);
Temperature Deviation: ±1.5℃ (no load and stable temperature);
Heating Up Time: +20℃→+85℃ ≤40 min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃ ≤60 min (No load, average nonlinearity);
WGDW SERIES High-Low Environmental Test Chambers (3C All-in-one)
Volume: 50L;
Material coding: WGDW-50L-40-5V30A16CH;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~100℃;
Temperature Fluctuation: ≤±0.5℃(no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→+100℃ ≤40 min(No load, average nonlinearity);
Cooling Time: +20℃→-40℃ ≤60 min (No load, average nonlinearity);
MGDW Series - High and Low Temperature Chambers (Standard)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
MGDW Series - High and Low Temperature Chambers (Humidity)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
MGDW Series - High and Low Temperature Chambers (Flameproof)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
MGDW Series - High and Low Temperature Chambers (Humidity & Flameproof)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing & Flameproof)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;
MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing, Flameproof & Humidity)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;
MGDW Series - High and Low Temperature Chambers (Double layer standard)
Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: 20℃~150℃; -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
MGDW Series - High and Low Temperature Chambers (Double layer Flameproof)
Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
MGDW Series - High and Low Temperature Chambers (Double layer Automatic Fire Extinguishing & Flameproof)
Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;