Constant Integrated Environmental Test Chambers .
25L constant integrated temperature test chambers
Test Method: GB/T 5170.2-2017;
Temperature Range: 15℃~60℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→60℃≤30min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
200L constant integrated temperature test chambers
Test Method: GB/T 5170.2-2017;
Temperature Range: 0~60℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→60℃≤30min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
300L constant integrated temperature test chambers
Test Method: GB/T 5170.2-2017;
Temperature Range: 0~60℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→60℃≤30min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
500L constant integrated temperature test chambers
Test Method: GB/T 5170.2-2017;
Temperature Range: 0~85℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→85℃≤40min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
Constant Split Environmental Test Chambers .
25L Constant Temperature Split Test Chambers
Test Method: GB/T 5170.2-2017;
Temperature Range: -20℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-20℃≤45min (No load, average nonlinearity);
480L Constant Temperature Split Test Chambers
Test Method: GB/T 5170.2-2017;
Temperature Range: 0~85℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→85℃≤40min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
480L Constant Temperature Split Test Chambers(Export Version)
Test Method: GB/T 5170.2-2017;
Temperature Range: 0~85℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→85℃≤40min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
Dual Temperature Zone Constant Temperature Integrated Chambers
Test Method: GB/T 5170.2-2017;
Temperature Range: 0~60℃;
Temperature Fluctuation: ≤1℃ (Equivalent to ±0.5℃, under no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→60℃≤30min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50 min (No load, average nonlinearity);