Chat or Call
Mint Wu
Sales Manager - Mint Wu skypelive:.cid.d7553a84e2f43ba0
  • Phone
    Phone
    0013235717558
    Call me
  • WeChat
    Scan QR code and add WeChat
    Mint_Wu-Neware
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-15196333435
    WhatsApp
  • E-mail
    E-mail
    mint.wu@neware.com.cn
    Send Email
Damon Yao
Sales Manager - Damon Yao skypelive:damonyao_2
  • Phone
    Phone
    +86-13924617429
    Call me
  • WeChat
    Scan QR code and add WeChat
    +86-13924617429
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-13924617429
    WhatsApp
  • E-mail
    E-mail
    yaoyihan@neware.com.cn
    Send Email
icon
Mint Wu
Sales Manager - Mint Wu skypelive:.cid.d7553a84e2f43ba0
  • Phone
    Phone
    0013235717558
    Call me
  • WeChat
    Scan QR code and add WeChat
    Mint_Wu-Neware
    WeChat
  • whatapp
    Scan QR code and add WhatsApp
    +86-15196333435
    WhatsApp
  • E-mail
    E-mail
    mint.wu@neware.com.cn
    Send Email
Damon Yao
Sales Manager - Damon Yao skypelive:damonyao_2
  • Phone
    Phone
    +86-13924617429
    Call me
  • WeChat
    Scan QR code and add WeChat
    +86-13924617429
    WeChat
  • whatapp
    Scan QR code and add WhatsApp
    +86-13924617429
    WhatsApp
  • E-mail
    E-mail
    yaoyihan@neware.com.cn
    Send Email
Damon Yao
Sales Manager - Damon Yao skypelive:damonyao_2
  • Phone
    Phone
    +86-13924617429
    Call me
  • WeChat
    Scan QR code and add WeChat
    +86-13924617429
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-13924617429
    WhatsApp
  • E-mail
    E-mail
    yaoyihan@neware.com.cn
    Send Email
icon
Select location or language
icon
Power Cell Testing
CT-4008-5V60A-NTA
  • Each Unit Size (W*D*H)(mm)
  • AC Input
    AC 220V ±10% / 50Hz
  • Input Active Power
    4253W
  • Resolution
    AD:16bit;DA:16bit
  • Input Impedance
    ≥1MΩ
  • Voltage

    Constant Voltage Range Control: 0.025V~5V;

    Minimum Discharge Voltage: 2.5V;

    Accuracy: ± 0.1% of FS;

    Stability: ± 0.1% of FS;

  • Current

    Output Range per Channel: 0.3A~60A;

    Accuracy: ± 0.1% of FS;

    Constant Voltage Cut-off Current: 0.12A;

    Stability: ± 0.1% of FS;

  • Power

    Single Channel Maximum Output Power: 300W;

    Stability: ± 0.2% of FS;

  • Time

    Current Response Time (10%FS~90%FS)

    Maximum current rise time: 20ms;


    Step Time Range

    ① ≤(365*24) h/step; ②Time Format Support  00:00:00:00(h, min, s, ms)

  • Data Acquisition

    Data Acquisition Conditions

    Minimum Time Interval: 100ms;

    Minimum Voltage Interval: 10mV;

    Minimum Current Interval: 120mA;


    Data Acquisition Frequency

    10Hz;

  • Charge

    Charging Mode: Constant Current Charging, Constant Voltage Charging, Constant Current/ Constant Voltage Charging, Constant Power Charging;

    Cut-off Conditions: Voltage, Current, Relative Time, Capacity, -△V;


  • Discharge

    Discharge Mode: Constant Current Discharge, Constant Voltage Discharge, Constant Power Discharge and Constant Resistance Discharge;

    Cut-off Conditions: Voltage, Current, Relative Time, Capacity;

  • Pulse Mode

    Charging: Constant Current Mode and Constant Power Mode;

    Discharge: Constant Current Mode and Constant Power Mode;

    Minimum Pulse Width: 500ms;

    Number of Pulses: A Single Pulse Step Supports 32 Different Pulses;

    Continuous Switching of Charge and Discharge: One Pulse Step can Realize Continuous Switching from Charge to Discharge;

    Cut off Conditions: Voltage, Relative Time;

  • Cycle Life

    Cycle Test Range: 1~65535 times;

    Number of Single Cycle Steps: 254;

    Loop Nesting: It has the Function of Nested Loop and Supports Up to 3 Levels of Nesting;

  • DCIR Test
    Support DCIR calculating with user defined point.
  • Protect

    Power down data protection;

    Function of prevention of feedback;

    The safety protection conditions can be set, and the setting specs include: voltage upper limit, voltage lower limit, current upper limit, current lower limit and delay time;

    Function of offline test.

  • IP Protection Degree
    Protection Degree: IP20
  • Channel Characteristics
    Constant current and constant voltage adopt double closed loop structure.
  • Channel Control Mode
    Independent Control
  • Voltage and Current Sampling
    Four Wire Connection
  • Noise
    <85dB
  • Database
    Adopting MySQL database to centralized manage testing data.
  • Server Disk Configuration
    500GB
  • Communication Mode of Upper Computer
    Based on TCP/ IP Protocol
  • Leakage Current
    0.005mA
  • Server Operating System
    Windows 7
  • Data Output Mode

    EXCEL 2003, 2010; 

    TXT.

  • Communication Interface
    Network Interface
  • Total Number of Channels
    8
  • Working Temperature Range
    0℃~40℃(Within the range of 25±10℃, accuracy drift is 0.005% of FS /℃)
  • Storage Temperature Range
    -10℃~50℃
  • Relative Humidity Range of Working Environment
    ≤70% RH(There is no condensation of moisture.)
  • Relative Humidity Range of Storage Environment
    ≤80% RH(There is no condensation of moisture.)
Neware and Cookies