Select location or language
icon
AUX auxiliary testing system
CA-4032n-1U-T-TC
  • Test Content
  • Test Content
    Temperature
  • Temperature

    Test Range

    Thermocouple: -200℃~260℃;

    Accuracy

    ± 1℃ (Line length within 2m);

    Temperature Resolution

    0.1℃;

  • Sampling Frequency
    10Hz/100ms
  • Can be run with equipment

    Charge and discharge cut-off conditions: temperature;

    Protection conditions: upper temperature limit, lower temperature limit,;

    Data output: Excel, TXT (temperature and main channel test data are bound);

    Channel mapping: The auxiliary channel can be bound to any main channel under the same central computer. Each main channel can be bound to up to 248 temperature/voltage auxiliary channels;

  • Communication Method
    RS485
  • IP Protection Level
    Protection Level IP20
  • Number of Channels of the Equipment
    32
  • Equipment working environment requirements
  • Input Power
    15W
  • Working Temperature Range
    0℃~40℃  (in the range of 25±10℃, measurement accuracy is guaranteed, accuracy drift: 0.005% of FS /℃)
  • Storage Temperature Range
    -10℃~50℃;
  • Relative Humidity Range of Working Environment
    ≤70% RH (No water vapor Condensation)
  • Storage Environment Relative Humidity Range
    ≤80% RH (No Water Vapor Condensation)
  • Clamp Specifications and Dimensions
  • Probe Type
    Thermocouple
Neware and Cookies
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies.Read our private policy

Neware Official Website