Chat or Call
Damon Yao
Sales Manager - Damon Yao skypelive:damonyao_2
  • Phone
    Phone
    +86-13924617429
    Call me
  • WeChat
    Scan QR code and add WeChat
    +86-13924617429
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-13924617429
    WhatsApp
  • E-mail
    E-mail
    yaoyihan@neware.com.cn
    Send Email
Mint Wu
Sales Manager - Mint Wu skypelive:.cid.d7553a84e2f43ba0
  • Phone
    Phone
    +86-19854480269
    Call me
  • WeChat
    Scan QR code and add WeChat
    azz2369210631
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-13048860917
    WhatsApp
  • E-mail
    E-mail
    mint.wu@neware.com.cn
    Send Email
icon
Damon Yao
Sales Manager - Damon Yao skypelive:damonyao_2
  • Phone
    Phone
    +86-13924617429
    Call me
  • WeChat
    Scan QR code and add WeChat
    +86-13924617429
    WeChat
  • whatapp
    Scan QR code and add WhatsApp
    +86-13924617429
    WhatsApp
  • E-mail
    E-mail
    yaoyihan@neware.com.cn
    Send Email
Mint Wu
Sales Manager - Mint Wu skypelive:.cid.d7553a84e2f43ba0
  • Phone
    Phone
    +86-19854480269
    Call me
  • WeChat
    Scan QR code and add WeChat
    azz2369210631
    WeChat
  • whatapp
    Scan QR code and add WhatsApp
    +86-13048860917
    WhatsApp
  • E-mail
    E-mail
    mint.wu@neware.com.cn
    Send Email
Mint Wu
Sales Manager - Mint Wu skypelive:.cid.d7553a84e2f43ba0
  • Phone
    Phone
    +86-19854480269
    Call me
  • WeChat
    Scan QR code and add WeChat
    azz2369210631
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-13048860917
    WhatsApp
  • E-mail
    E-mail
    mint.wu@neware.com.cn
    Send Email
icon
Select location or language
icon
CE-6000
Module&Pack
Regenerative Charge and Discharge Battery Testing System
High Frequency Isolation 10V~120V
Neware Battery Pack Tester
It has the characteristics of high dynamic response speed, high stability precision and multi-channel flexible configuration which also supports pulse test, cycle life test and simulation test. The system has the function of multi-channel input and energy recovery, which can save a lot of electric energy consumed in the process of charging and discharging. Using bidirectional high-frequency DC converter topology and high-performance multi-channel 24 bit AD converter chip, the sampling resolution is higher than that of traditional single range equipment.
Use data to interprete module testing
  • Neware Battery Pack Tester
    100Hz
    Data Acquisition Frequency
  • Neware Battery Pack Tester
    RS485 Communication
    CANBus
  • Neware Battery Pack Tester
    >90%
    Energy Conversion Efficiency
  • Neware Battery Pack Tester
    Simulation
  • Neware Battery Pack Tester
    Support
    BMS Docking
  • Neware Battery Pack Tester
    ≥0V
    Discharge Voltage
  • Neware Battery Pack Tester
    0.02%/0.05%
    Accuracy
  • Neware Battery Pack Tester
    100ms
    Min. Pulse Width
  • Neware Battery Pack Tester
    ≤3ms
    Response Time
  • Neware Battery Pack Tester
    Parallel Channels
  • Neware Battery Pack Tester
  • Neware Battery Pack Tester
    Lithium batteries for electric vehicles
  • Neware Battery Pack Tester
    Lithium battery for electric bicycle
  • Neware Battery Pack Tester
    Lithium battery for power tools
  • Neware Battery Pack Tester
    Lithium batteries for garden tools
  • Neware Battery Pack Tester
    Energy storage lithium battery
Delivering at once
Regenerative Charge and Discharge Module & PACK Testing System
Delivering at once
Low Frequency Isolation 60V~1200V Module & PACK Battery Testing System
Delivering at once
Low Frequency Isolation 60V~1200V Module & PACK Battery Testing System
Model Description
C
Product
T
①T/Empty
E
-
60
6 Series Module
&Pack
04
Number of Channels
X
②D/T/Q/Empty
n
③n/m
-
□□□V
Maximum Output Voltage
(V)
□□□A
Maximum Output Current
(A)
-
IG
IGBT
-
B/F
Charge and Discharge Separation/
Discharge voltage below 0V
①T-Accuracy: 0.02%FS;Empty-Default Accuracy: 0.05%FS or 0.1%FS;
②D-Double Range;T-3 Range;Q-4 Range; Empty-Single Range;
③n-100Hz;m-10Hz;
C
T
E
-
60
04
X
n
-
□□□V
□□□A
-
IG
-
B/F
①Product
②T/Empty
③6 Series Module&Pack
④Number of Channels
⑤D/T/Q/Empty
⑥n/m
⑦Maximum Output Voltage (V)
⑧Maximum Output Current (A)
⑨IGBT
⑩Charge and Discharge Separation/ Discharge voltage below 0V
Typical Model
60V20A 60V30A 60V50A 60V60A 60V100A 60V120A
60V400A 60V240A 120V50A 120V100A 120V200A 120V400A
200V50A 500V100A 200V200A 400V200A 750V500A 800V600A
-B (Charge and Discharge Port) / -F (Negative Pressure) Optional Functions
Software
Essential components
Neware Battery Pack Tester
Neware Battery Pack Tester
Neware Battery Pack Tester
Neware Battery Pack Tester
Neware Battery Pack Tester
Neware Battery Pack Tester
Neware Battery Pack Tester
Neware Battery Pack Tester
DBC Configuration Function
Discharge to 0V
Constant Current Charge/Discharge Test
Constant Current/Voltage Charge/Discharge test
100ms Pulse Width
CCDC
CCCV
Simulation
dQ/dV微分容量曲线:曲线上出现峰的地方表示充放电曲线有电压平台,不同的峰代表不同的电化学反应。
在诸多的测试应用中,要同时对多个条件进行判断,根据不同的测量结果响应不同的操作;条件工步满足的条件为多出口的编程方式。与(&&)或(||)逻辑运算,“≥”、“≤”、“=” 比较运算;持续时间“t”,可实现特殊测试的控制要求;每个工步支持5个条件工步;支持多个出口,go to 到任意工步,实现更加灵活的流程控制。
支持以电压、电流、时间分段进行数据记录;每1工步可设置3个分段记录条件;每个分段可设置:△T/△V/△I。
BTS Server 通过交换机对外围设备(检测设备、自动压床)的通信控制。
Q的单位为库仑,1库仑=1A*1s=1As(安秒);1Ah=3600As(安秒);工作电压U=充电上限电压-放电下限电压;工作电压可设置,软件自动计算电容容值(C)。
支持以电压、电流、时间分段进行数据记录;每1工步可设置3个分段记录条件;每个分段可设置:△T/△V/△I。
BTS Server 通过交换机对外围设备(检测设备、自动压床)的通信控制。
dQ/dV微分容量曲线:曲线上出现峰的地方表示充放电曲线有电压平台,不同的峰代表不同的电化学反应。
Modularization of Power Unit
1Modular design is convenient to maintain equipment.
2DC and AC modules are used together, DC BUS is independent;
3Copper bar technology makes the equipment interior much cleaner.
Neware Battery Pack Tester
System Protection
Power Grid Over/Under-voltage, AC
Short Circuit, Phase Protection
Power Grid Voltage Phase Sequence and Frequency Self Adaptation
Overheat Protection
Open/Short Circuit Protection
Emergency Stop Protection
Voltage and Current Protection Value can be Set
Neware Battery Pack Tester
Output Overvoltage/Overcurrent Protection
Channel Redundant Voltage Protection
DC Acute Reverse Connection Protection
Self-checking Protection
Equipment Power off Continuity Protection
Protection Log Traceability
Integrated Operation and Collaborative Work through BTS Upper Computer Control System
NEWARE battery charge and discharge test system realizes integrated operation and collaborative work through BTS upper computer control system, so as to maximize the battery characteristics and functions.
Neware Battery Pack Tester Neware Battery Pack Tester
Neware Battery Pack Tester Neware Battery Pack Tester Neware Battery Pack Tester
Peripheral Linkage
1BMS Protection Board Linkage
2Thermostat Linkage
3Water Cooling Machine Linkage
4Balance Equipment Linkage
Neware Battery Pack Tester
Close to 100% Energy Recovery
Full Power Feedback Technology; Energy-feedback efficiency is more than 90%; Battery discharge energy is recycled and used for charging in other channels. If there is energy surplus, it will be fed back to the grid.
Neware Battery Pack Tester
Size & Weight
① W*D*H: 600*800*1800(mm);Weight: 300kg.
② W*D*H : 600*800*1200(mm), Weight: 200kg. a
Neware Battery Pack Tester
Neware and Cookies
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies.Read our private policy

Neware Official Website